829 Seabury - HomeGuard Inspection List: Difference between revisions

From dtype.org
(interior section)
Line 59: Line 59:
|
|
| The fence is in satisfactory condition, however one or more of the fence posts are loose. We recommend all loose, damaged or deteriorated post be reinforced or replaced as necessary.
| The fence is in satisfactory condition, however one or more of the fence posts are loose. We recommend all loose, damaged or deteriorated post be reinforced or replaced as necessary.
|}
== Interior ==
{| class="wikitable"
! style="text-align:left;"| Priority
! Status
! Who
! Description
|-
| style="color: green;" | Low
| Postpone
|
| The openings in the railing are larger than 4". For improved safety it is recommended that the railing be altered for an opening of less than 4".
|}
|}



Revision as of 14:35, 20 April 2017

List of things to accomplish at 829 Seabury before moving in, or just after moving in:

Plumbing

Priority Status Who Description
High The kitchen sink drain is leaking into the crawl space. We recommend all leaks be repaired.

Exterior

Priority Status Who Description
Low Joe? The pet door within the garage passage door is a breech in the fire separation between the garage and the living area. The opening is near the floor and may not significantly increase the risk of fire spreading. However, we recommend replacement of the passage door.
Medium The base of the support post(s) for the deck/porch cover or overhang are water damaged. We recommend the advice and services of licensed contractor and/or structural pest control company.
Medium Water damage was observed to the exterior trim at the front. We recommend the services of a licensed general contractor and/or structural pest control company.
Low Damage was observed in the planter shelf. We recommend the advice and services of the appropriate trades regarding repairs to this area.
Medium Damaged or cracked trim was noted at the right exterior We recommend the trim be repaired or replaced.
Medium The patio cover is not adequately braced and is wobbly when pushed from side to side. We recommend the patio cover be strengthened to resist lateral movement.
Medium The fence is in satisfactory condition, however one or more of the fence posts are loose. We recommend all loose, damaged or deteriorated post be reinforced or replaced as necessary.

Interior

Priority Status Who Description
Low Postpone The openings in the railing are larger than 4". For improved safety it is recommended that the railing be altered for an opening of less than 4".

Electrical

Priority Status Who Description
Low Drew The missing outlet cover plates at the master bathroom should be replaced. Based upon our inspection of a representative number of outlets we recommend checking every outlet to make sure they all have covers.

Heating

Priority Status Who Description
Medium The gas connector for the furnace is aluminum tubing. This does not meet present standards. We recommend replacing the supply line with a flexible approved gas line meeting present standards.